<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-16 17-39-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 53 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.8 kHz -9 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
17 kHz 72 kHz 10080 4,2758
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,7 dBr 7,73 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 17:39, 16.07.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (53 dBuV) Max at: 72 kHz MIN: 17 kHz % above 75 kHz: 4,2758 Acquired: 2025/07/16 17:38:16 Total samples: 10080 Equivalent time: 0:08:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,3 dBr MIN: 6,7 dBr AVE: 7,73 dBr % above 10,2 dBr: 0,0 Last value: 8,3 dBr (2025/07/16 17:38:16) Station: 96.90 MHz, signal: 5/5 (54 dBuV) 17:31 17:32 17:33 17:34 17:35 17:36 17:37 17:38 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality